Below is a structured, GMP-aligned Equipment Safety Protocol for Supercritical CO₂ Extraction (SFE) systems, suitable for training manuals, SOPs, audits, and operator certification.
Equipment Safety Protocols for Supercritical CO₂ Extraction (SFE)
1. Safety Philosophy (Golden Rules)
- Pressure is the primary hazard — treat all pressurized components as energized.
- Automation reduces risk, but does not replace vigilance.
- Never defeat interlocks or alarms.
- No maintenance on pressurized systems — ever.
2. Pre-Operation Safety Checks (Before Every Run)
A. System Integrity
- Verify vessel pressure rating > planned operating pressure
- Inspect:
- Seals, O-rings, gaskets
- Tubing and fittings (no scratches, kinks, corrosion)
- Filters and screens (clean, seated correctly)
B. Safety Devices
- Pressure Relief Valves (PRVs):
- Set below MAWP
- Not isolated or blocked
- Burst discs:
- Correct rating
- No deformation or corrosion
- Emergency stop (E-stop): tested and functional
C. Instrumentation
- Pressure transducers calibrated
- Temperature sensors functional
- Flow meters zeroed
- CO₂ detectors active (audible + visual alarms)
3. Safe Start-Up Protocol
- Confirm:
- Vessel properly closed and torqued
- Collection vessels secured
- Begin slow pressurization
- Ramp pressure gradually (no step changes)
- Monitor:
- Pressure rise rate
- Temperature stability
- Unusual noises or vibrations
- Verify stable operating conditions before extraction begins
⚠️ Abort start-up immediately if pressure spikes or temperature drifts abnormally.
4. Safe Operation Protocol
A. During Extraction
- Maintain operation within validated pressure–temperature window
- Monitor:
- Pressure drop across bed
- CO₂ flow consistency
- Separator conditions
- Never:
- Tighten fittings under pressure
- Bypass alarms
- Leave system unattended without alarms enabled
B. Automation & Interlocks
- PLC/SCADA must:
- Prevent over-pressure
- Shut down on sensor failure
- Enforce correct sequence (pressurize → extract → depressurize)
5. Safe Depressurization Protocol (MOST CRITICAL STEP)
- Depressurize slowly
- Controlled pressure ramp down
- Maintain temperature to avoid:
- Ice formation
- Seal embrittlement
- Vent CO₂ to:
- Designated exhaust
- Well-ventilated area
- Confirm zero pressure before opening any component
🚫 Never:
- Rapidly vent manually
- Open vessels without pressure verification
6. Maintenance & Servicing Safety
Lock-Out / Tag-Out (LOTO)
- Isolate CO₂ supply
- Depressurize system fully
- Lock valves and power sources
- Attach warning tags
Component Replacement
- Replace seals on a schedule (not on failure)
- Use manufacturer-approved parts only
- Pressure test after reassembly
7. Emergency Safety Protocols
A. CO₂ Leak
- Evacuate immediately
- Activate emergency ventilation
- Do not attempt repair
- Re-enter only after CO₂ sensor clearance
B. Over-Pressure Alarm
- Automatic shutdown
- Controlled depressurization
- Root cause investigation required before restart
C. Vessel or Fitting Failure
- Evacuate
- Lock out system
- Incident reporting & inspection
8. PPE Requirements (Last Line of Defense)
| PPE | Use |
|---|---|
| Face shield | Jet and fragment protection |
| Safety goggles | Eye protection |
| Cryogenic gloves | Cold burns |
| Cut-resistant gloves | Tubing & fittings |
| Hearing protection | Rapid venting |
9. Documentation & GMP Compliance
Required records:
- Daily pre-operation checklist
- Calibration certificates
- Maintenance logs
- Alarm and interlock testing records
- Operator training records
- Incident / deviation reports
Auditors expect:
- Traceability
- Preventive maintenance program
- Emergency drills documentation
10. Safety Inspection Checklist (Summary)
✔ Vessel rating verified
✔ PRVs & burst discs active
✔ CO₂ detectors working
✔ Alarms tested
✔ Ventilation operational
✔ SOP followed
✔ Operator trained
Final Safety Rule
If you are unsure — STOP.
Pressure systems do not forgive improvisation.
Bottom Line
Safe SFE operation depends on engineering controls, disciplined procedures, trained operators, and documentation. Equipment safety protocols must be non-negotiable and auditable, especially under GMP and industrial operation.